6.00A.020.002 - AudioCodes Mediant 2000 SIP Digital Gateway
1 Important Notes
Check the SIP 3
rd
Party Validation Website for current validation status. The
SIP 3
rd
Part Validation Website can be viewed at:
http://testlab.inin.com or http://testlab.vonexus.com
It is recommended to make basic changes to the I3 supplied .ini file then
utilize the web interface for further configuration.
As this unit is a critical piece of the SIP infrastructure, it is highly
recommended that DHCP not be used. A static IP address is the preferred
method and is how the unit was configured during validation.
After a factory reset, the Mediant 2000 will default to G.729 as its primary
codec
The option for clock master is not exposed in the web interface. The settings
in the I3 supplied .ini file are to derive clock from the PSTN connection.
Should the internal oscillator be required, refer to INI Parameters Section of
this document, specifically the TDMBusClockSource, ClockMaster and
ClockMaster_x parameters.
When using SRTP the number of available E1 channels is decreased. See
Security section 8 below.
2 Vendor Documentation
Documentation can be found on the CD shipped with the Mediant 2000.
3 Validated Firmware Version
V 6.00A.020.002
4 Install
Download the Mediant 2000 files from the Interactive Intelligence Testlab
website for the M2K:
http://testlab.inin.com/FeatureListPage.aspx?ProductType=1&ProductIDs=87
Contained in the zip file will be the validated version of firmware (.cmp), as
well as any supplemental configuration files, and a sample .ini file.