Microsoft Lync and ThinkTel SIP Trunk 55 June 2012
Microsoft Lync and ThinkTel SIP Trunk 4. Configuring the E-SBC Device
4.13 Step 13: Configuring Miscellaneous Parameters
This step shows how to configure miscellaneous parameters for SBC functionality.
¾ To configure Disconnect Parameters:
1. Open the Advance Parameters page (Configuration tab > VoIP menu > SIP
Definitions > Advance Parameters).
Figure 4-34: Disconnect Parameters Screen
2. From the ‘Disconnect on Broken Connection’ drop-down list, select No (it's mandatory
to set this field in a Lync environment). It determines whether the device releases the
call if RTP packets are not received within a user-defined timeout.
¾ To configure AdminPage parameters:
1. Open the Admin page: Append the case-sensitive suffix ‘AdminPage’ to the device's
IP address in your Web browser's URL field (e.g., http://10.15.45.201/AdminPage).
2. In the left pane click ini Parameters:
Figure 4-35: INI File Output Window
3. Enter these values in the 'Parameter Name' and 'Enter Value' fields:
Parameter Value
SBCFORKINGHANDLINGMODE
Enter 1. Determines if 18x with SDP is received, the device opens a
voice stream according to the received SDP. The device reopens the
stream according to subsequently received 18x responses with SDP,
or plays a Ringback tone if 180 response without SDP is received. It's
mandatory to set this field for the Lync environment.
4. Click Apply New Value for this parameter.
4