Fast Track Installation Guide 3. Configuring the MP-1xx
Version 4.6 17 July 2005
12. Use the reset button (located on the MP-1xx front panel) to physically reset the gateway
causing it to use BootP; the MP-1xx changes its network parameters to the values provided
by the BootP.
Figure
3-1: Client Configuration Screen with Blank Parameters
3.1.3 Assigning an IP Address Using the CLI
First access the CLI using a standard Telnet application or using a serial communication software
(e.g., HyperTerminal
TM
) connected to the MP-1xx RS-232 port (refer to Section 3.1.3.1 below).
Then assign the MP-1xx an IP address (refer to Section
3.1.3.2 on page 18).
3.1.3.1 Access the CLI
¾ To access the CLI via the Embedded Telnet Server, take these 3 steps:
1. Enable the Embedded Telnet Server:
¾ Access the MP-1xx Embedded Web Server (refer to Section
3.3 on page 19).
¾ Set the parameter ‘Embedded Telnet Server’ (under Advanced Configuration >
Network Settings > Application Settings) to ‘Enable (Unsecured)’.
¾ Click the Reset button on the main menu bar; the Reset screen is displayed.
¾ Click the Reset button in the middle of the Reset screen with the Burn option selected;
the MP-1xx is shut down and re-activated. A message about the waiting period is
displayed. The screen is refreshed.
2. Use a standard Telnet application to connect to the MP-1xx Embedded Telnet Server.
3. Login using the username (‘Admin’) and password (‘Admin’).