Fast Track Installation Guide 3. Configuring the MP-1xx
Version 4.6 23 July 2005
3.4.3 Configuring Basic SIP Parameters
After accessing the Embedded Web Server (refer to Section 3.3 on page 19) the SIP ‘Quick
Setup’ screen is displayed, shown in Figure
3-5.
Figure
3-5: MP-1xx SIP Quick Setup Screen
¾ To configure basic SIP parameters, take these 9 steps:
1. If the MP-1xx is connected to a router with NAT enabled, perform the following procedure. If
it isn’t, leave the ‘NAT IP Address’ field undefined.
¾ Determine the “public” IP address assigned to the router (by using, for instance, router
Web management). Enter this public IP address in the ‘NAT IP Address’ field.
¾ Enable the DMZ configuration on the residential router for the LAN port where the MP-
1xx gateway is connected. This enables unknown packets to be routed to the DMZ port.
2. Under ‘SIP Parameters’, enter the MP-1xx Domain Name in the field ‘Gateway Name’. If the
field is not specified, the MP-1xx IP address is used instead (default).
3. When working with a Proxy server, set ‘Working with Proxy’ field to ‘Yes’ and enter the IP
address of the primary Proxy server in the field ‘Proxy IP Address’. When no Proxy is used,
the internal routing table is used to route the calls.
4. Enter the Proxy Name in the field ‘Proxy Name’. If Proxy name is used, it replaces the Proxy
IP address in all SIP messages. This means that messages are still sent to the physical
Proxy IP address but the SIP URI contains the Proxy name instead.
5. Configure ‘Enable Registration’ to ‘Yes’ or ‘No’:
‘No’ = the MP-1xx does not register to a Proxy server/Registrar (default).
‘Yes’ = the MP-1xx registers to a Proxy server/Registrar at power up and every ‘Registration
Time’ seconds. The MP-1xx sends a register request according to the ‘Authentication Mode’
parameter. For detailed information on the parameters ‘Registration Time’ and
‘Authentication Mode’, refer to the MP-1xx SIP User’s Manual.