AudioCodes Mediant 3000 Bedienungsanleitung Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 78
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
Configuration Note 4. Configuring AudioCodes E-SBC
Microsoft Lync and XO Technology SIP Trunk 63 AudioCodes Mediant E-SBC
4. Click the Action tab, and then configure the parameters as follows:
Parameter Value
Prefix to Add
+ (plus sign)
Figure 4-36: Configuring IP-to-IP Outbound Manipulation Rule - Action Tab
5. Click Submit.
The figure below shows an example of configured IP-to-IP outbound manipulation rules for
calls between IP Group 1 (i.e., Lync Server 2013) and IP Group 2 (i.e., XO
Communications SIP Trunk):
Figure 4-37: Example of Configured IP-to-IP Outbound Manipulation Rules
Rule Index Description
0
Calls from IP Group 2 to IP Group 1 with any destination number (*), add "+" to the
prefix of the destination number.
1
Calls from IP Group 1 to IP Group 2 with the prefix destination number "+", remove "+"
from this prefix.
2
Calls from IP Group 1 to IP Group 2 with source number prefix "+", remove the "+" from
this prefix.
Seitenansicht 62